Fire Door Awareness training course
Fire Door Awareness is a 50-minute online awareness course covering what fire doors do, the law, routine checks, hold-open devices and defects and limits. This course is for people who carry out routine fire door checks, such as caretakers, facilities and maintenance staff, building managers' teams and care home maintenance staff, and for anyone whose job includes reporting fire door defects. It is included in the Complete and Construction plans.
- Length: 50 minutes
- Format: online, any device
- Level: awareness
- Assessment: 15 questions, 80% to pass
What you will learn
By the end of the course you should be able to:
- Explain what a fire door does, why it must close fully into its frame and latch, and how its parts work, including the self-closer, intumescent strips, smoke seals, hinges, glazing, signs and hold-open devices.
- Describe the law on fire door maintenance and reporting: the responsible person's duty under article 17 of the Fire Safety Order, your own duties under article 23, how this applies in Wales, and where Scotland and Northern Ireland have their own law.
- Describe the fire door duties in regulation 10 of the Fire Safety (England) Regulations 2022: information for residents, 3-monthly checks of communal fire doors and best-endeavours 12-monthly checks of flat entrance doors in blocks above 11 metres, in England only.
- Describe the routine visual checks set out in government guidance, including the self-closer test, gaps, strips and seals, hinges, glazing, letterboxes, signs, wedges and hold-open devices, and how to record what you find.
- Explain what to do when you find a defect, including reporting, recording and taking only the interim steps your procedure allows, and recognise the work this course does not make you competent to do.
What the course covers
The course has 5 modules:
- What a fire door does and how its parts work: how a fire door protects people, it must close fully and latch, the parts you will check and fire doors in a block of flats.
- The law: maintenance, your duties and the 2022 Regulations: the Fire Safety Order, flat entrance doors since 2021, the Fire Safety (England) Regulations 2022, offices, care homes and hotels and scotland and Northern Ireland.
- Routine visual checks and records: who does the checks, what to look at, checks in workplaces and record what you find.
- Hold-open devices, care homes and hotels: hold-open and free-swing devices, checking held-open doors, care homes and hotels.
- When you find a defect, and the limits of your role: when you find a defect.
How it is assessed
The course ends with a final assessment of 15 questions drawn from a bank of 40, with at least 2 on every learning outcome, so a retake gets a different paper. The pass mark is 80% (12 correct answers out of 15).
This certificate evidences completion of an awareness-level course only. It does not, by itself, confirm practical competence, authorisation, or a professional qualification, and does not replace formal or accredited training, competent advice, supervision or role-specific instruction where required.
Who it is for and what it does not replace
This course is for people who carry out routine fire door checks, such as caretakers, facilities and maintenance staff, building managers' teams and care home maintenance staff, and for anyone whose job includes reporting fire door defects.
This is awareness training for people who carry out routine visual checks of fire doors and people who report fire door defects. It supports, but does not replace, the instruction your employer must give you for your own buildings, checklist and reporting procedure.
This course does not make you competent to inspect fire doors as a specialist, to judge whether a door's fire resistance is adequate, or to repair, adjust, re-hang, re-glaze, alter or replace a fire door or any of its parts, including closers, seals, hinges and hold-open devices. It does not make you competent to certify or sign off a door as compliant. Repairs and replacements need a competent person, and the government guidance says the routine checks are not a substitute for periodic assessment of fire doors by fire safety specialists. The course also does not cover carrying out a fire risk assessment, or testing and servicing fire alarm systems or the release mechanisms of hold-open devices.
How often to refresh
Organisational choice: Featherstone's suggested review point, not set by law. Suggested interval: every 12 months. No fixed legal refresher period. Article 21 of the Fire Safety Order requires training when an employee is given a change of responsibilities that exposes them to new or increased risks, repeated periodically where appropriate. Regulation 10 of the Fire Safety (England) Regulations 2022 sets no training requirement for the people who carry out the checks. Featherstone Safety suggests a refresher every 12 months, in line with Fire Safety Awareness and Fire Warden, and sooner when the government fire door guidance changes (it was last revised in August 2025), your buildings change or your role changes.
Law and guidance this course draws on
Where it applies. England and Wales: the Regulatory Reform (Fire Safety) Order 2005, including article 17 (maintenance), article 23 (employees) and article 32 (offences). Section 1 of the Fire Safety Act 2021, which brought flat entrance doors within the Order, has been in force in Wales since 1 October 2021 and in England since 16 May 2022. The Fire Safety (England) Regulations 2022, including regulation 10 (fire doors), extend to England and Wales but apply in England only. The main provisions of the Building Safety (Wales) Act 2026, which will bring in new duties for blocks of flats in Wales, come into force by order and were not in force when this course was checked (14 November 2026). Scotland has its own law: Part 3 of the Fire (Scotland) Act 2005 and the Fire Safety (Scotland) Regulations 2006 (regulation 16 maintenance, section 56 and regulation 22 employees). Northern Ireland has its own law: Part III of the Fire and Rescue Services (Northern Ireland) Order 2006 and the Fire Safety Regulations (Northern Ireland) 2010 (regulation 16 maintenance, article 28 and regulation 22 employees). In Scotland and Northern Ireland this law does not normally cover the common parts of an ordinary block of flats: section 78 of the 2005 Act and article 50 of the 2006 Order exclude domestic premises, including stairs and passages used in common by the occupants of more than one dwelling.
- The Regulatory Reform (Fire Safety) Order 2005, article 17 (maintenance), legislation.gov.uk
- The Regulatory Reform (Fire Safety) Order 2005, article 23 (general duties of employees at work), legislation.gov.uk
- The Regulatory Reform (Fire Safety) Order 2005, article 32 (offences), legislation.gov.uk
- The Regulatory Reform (Fire Safety) Order 2005, article 1 (extent: England and Wales), legislation.gov.uk
- The Regulatory Reform (Fire Safety) Order 2005, article 6 (application to premises, as amended by the Fire Safety Act 2021), legislation.gov.uk
- The Regulatory Reform (Fire Safety) Order 2005, article 21 (training), legislation.gov.uk
- Fire Safety Act 2021, section 1, legislation.gov.uk
- The Fire Safety Act 2021 (Commencement) (Wales) Regulations 2021, regulation 2 (section 1 in force in Wales on 1 October 2021), legislation.gov.uk
- The Fire Safety Act 2021 (Commencement) (England) Regulations 2022, regulation 2 (section 1 in force in England on 16 May 2022), legislation.gov.uk
- The Fire Safety (England) Regulations 2022, regulation 10 (fire doors), legislation.gov.uk
- The Fire Safety (England) Regulations 2022, regulation 1 (commencement, extent and application: England only), legislation.gov.uk
- The Fire Safety (England) Regulations 2022, regulation 3 (measuring height), legislation.gov.uk
- Fire Safety (England) Regulations 2022: fire door guidance (revised 8 August 2025), Ministry of Housing, Communities and Local Government and Home Office (GOV.UK)
- Fire doors checklist, Ministry of Housing, Communities and Local Government and Home Office (GOV.UK)
- Fact sheet: Fire doors (regulation 10), Home Office (GOV.UK)
- Fire Safety (England) Regulations 2022, Home Office (GOV.UK)
- Fire safety in the workplace, GOV.UK
- Fire safety risk assessment: offices and shops, Home Office (GOV.UK)
- Fire safety risk assessment: residential care premises, Home Office (GOV.UK)
- Fire safety risk assessment: sleeping accommodation, Home Office (GOV.UK)
- Fire (Scotland) Act 2005, section 78 (meaning of relevant premises: domestic premises excluded), legislation.gov.uk
- The Fire and Rescue Services (Northern Ireland) Order 2006, article 50 (meaning of relevant premises: domestic premises excluded), legislation.gov.uk
- Building Safety (Wales) Act 2026, sections 1 and 138 (overview of Part 1, coming into force), legislation.gov.uk
- The Fire Safety (Scotland) Regulations 2006, regulation 16 (maintenance), legislation.gov.uk
- The Fire Safety (Scotland) Regulations 2006, regulation 22 (duties of employees), legislation.gov.uk
- Fire (Scotland) Act 2005, section 56 (duties of employees), legislation.gov.uk
- The Fire Safety Regulations (Northern Ireland) 2010, regulation 16 (maintenance), legislation.gov.uk
- The Fire Safety Regulations (Northern Ireland) 2010, regulation 22 (duties of employees), legislation.gov.uk
- The Fire and Rescue Services (Northern Ireland) Order 2006, article 28 (duties of employees), legislation.gov.uk
Sources last checked 14 November 2026.
Included in your subscription
This course is part of the awareness training library, which is included in the Complete (£179 a month) and Construction (£249 a month) plans with all 53 courses and no charge per learner or per course, up to the plan's employee allowance. Passes are recorded on the training matrix automatically.
Try it free for 14 days. No card required. Courses can be taken during the 14-day trial of a plan that includes training, and completions are recorded as normal. Certificates are issued once the workspace has an active paid subscription.
Course version 2.0.0. Published 15 November 2026. Last reviewed 14 November 2026. Next review due 14 November 2027.